If you do not see the Material you need please contact This e-mail address is being protected from spambots. You need JavaScript enabled to view it
| Dimensions | Normal | Premium |
| Up to 1/4" | ± .005" | ± .003" |
| Up to 1" | ± .008" | ± .005" |
| Up to 2" | ± .010" | ± .008" |
| Up to 3" | ± .012" | ± .010" |
| Up to 4" | ± .014" | ± .012" |
| Up to 5" | ± .016" | ± .013" |
| Up to 6" | ± .018" | ± .014" |
| Up to 7" | ± .020" | ± .016" |
| Up to 8" | ± .022" | ± .017" |
| Up to 9" | ± .024" | ± .018" |
| Up to 10" | ± .026" | ± .019" |
*An exception to the standard linear tolerance exists on some wall thicknesses.
The tolerance must be a minimum of ± .010".
Flatness and straightness: Tolerances for flatness and straightness are 003" to .005" T.I.R per linear inch and depend on alloy and casting configuration
Angles: Angular tolerances should be specified ± 1/2° maximum
Concentricity
Perpendicularity
Parallelism
Radii and fillets
Roundness
Threads
Minimum section thickness .040” otherwise contact This e-mail address is being protected from spambots. You need JavaScript enabled to view it
Surface Texture 90-125 RMS
*Waltek uses Nadcap and Boeing Approved Processors upon request
| Waltek In Incast Magazine 10/31/2009 Waltek Inc. was recently featured in InCast Magazine. You can download the full article here! |
| Radioactive Co-60 Found in Stainless Steel Castings 08/31/2009 In recent months, Waltek was notified by a customer that radioactive material was found in stainless steel parts that were cast in India. This discovery was made as the parts were passing through Germ [ ... ] |
Loading Poll...We can help you decide if the investment casting process is the most efficient and economical way to produce your part. We'll also help you conform your design to the investment casting process, with expert advice on intricate and close tolerance designs, metallurgy, and tool requirements.
Get A QuotePrototype parts can be shipped in less than two weeks from your supplied CAD file.
Get a QuoteWith our complete Quality Control department, Waltek can remain highly competitive while maintaining ISO/AS quality standards. Waltek minimizes costs by providing non-destructive testing: dye penetrant, magnetic particle, and radiographic.
Read More